24
en | User Guide
AMAX panel 2000 / AMAX panel 2000 EN
F.01U.241.127 | V4 | 2011.12
Installation Manual
Bosch Sicherheitssysteme GmbH
4.1.3
Forced arming
Arming the system when a zone is not sealed is known as forced arming. If the AWAY indicator
does not glow, and if a long beep sounds when you attempt to arm the system in AWAY Mode,
then forced arming is not permitted. If this is the case, then you will have to seal all zones or
manually isolate them before you can arm the system.
Please contact your installer to enable/disable this function.
4.2
Disarming the System
4.2.1
Disarming with CODE
Enter your code and press [#] .Two beeps sound and the AWAY or STAY indicator is
extinguished.
4.2.2
Disarming with wireless control Key
Press and hold the Disarming Button. Two beeps sound and the AWAY or STAY indicator is
extinguished.
4.2.3
Disarming with Key switch
When the Key switch is deactivated, the system is disarmed and the AWAY or STAY indicator is
extinguished.
4.3
Faults or Tamper conditions
Whenever a system fault or tamper condition occurs, the FAULT or MAINS indicator flashes
and the keypad beeps.
4.3.1
System fault or tamper analysis Mode
To enter fault or tamper analysis mode for determining a system fault or tamper condition:
1.
Enter your Code and [2] and press [#]. Two beeps sound.The FAULT indicator remains lit
and the STAY and AWAY indicators flash. The lit zone indicators indicate the type of fault
or tamper condition that occurred.
2.
For a multi-level menu, enter the corresponding number to enter the submenu, press [0]
key to return to the main menu.
3.
To exit from Fault and Tamper Analysis Mode, press [#] . The STAY and AWAY indicators
are extinguished and the FAULT indicator remains lit, and the keypad stops the beep.
NOTICE!
Operation can be carried out only in disarmed status.
1
Accessory Modules Fail
1
Keypad 1 fail
2
Keypad 2 fail
3
DX 3010 Fail
4
B420/DX 4020 /-G Fail
2
Power Faults
1
AC Fault
2
Fault Battery
3
Aux Power Supply Fault
4
Bosch Option Bus Power Fault