Bosch Sicherheitssysteme GmbH
1.
Disarm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
2.
AWAY Arm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
Zone triggered - during exit time - Alarm / report
Zone triggered - during entry time - Alarm / report
3.
STAY Arm: Same as AWAY Arm performance.
A Tamper zone does not send a restore report until the zone is restored.
9- Fire Zone
The Fire zone will perform as below:
1.
Disarm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
2.
AWAY Arm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
Zone triggered - during exit time - Alarm / report
Zone triggered - during entry time - Alarm / report
3.
STAY Arm: Same as AWAY Arm performance.
A Fire zone does not send a restore report until the zone is restored.
10- External Fault Zone
The Fault Zone/Input will perform as below:
1.
Disarm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
2.
AWAY Arm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
Zone triggered - during exit time - Alarm / report
Zone triggered - during entry time - Alarm / report
3.
STAY Arm: Same as AWAY Arm performance.
The restore report will only be sent when the zone is restored and fault is reset.
11- Bolt Contact Zone
The Bolt-Contact zone will perform as below:
1.
Disarm:
Zone normal - no Alarm / no report
Zone triggered - no Alarm / no report
2.
AWAY Arm:
Zone normal - no Alarm / no report
Zone triggered - no Alarm / no report
Zone triggered - during exit time - no Alarm / no report
Zone triggered - during entry time - no Alarm / no report