74
en | System Informations 2
AMAX panel 2000 / AMAX panel 2000 EN
F.01U.241.127 | V4 | 2011.12
Installation Manual
Bosch Sicherheitssysteme GmbH
Figure 8.4
DX3010 Location Setting
8.6.6
B420/DX4020/ITS-DX4020G GSM GPRS Communication Module
The AMAX panel 2000 / AMAX panel 2000 EN Control Panel supports one B420 or one DX4020
network communication module or ITS-DX4020G GSM/GPRS communication module. Only
one can be selected to connect in one system to send reports thought the network.
Set in Location 134 to use B420/DX4020/ITS-DX4020G as below:
Figure 8.5
DX4020 Location Setting
ITS-DX4020G is configured by connecting with the PC. Refer to ITS-DX4020G manual for more
information.
8.6.7
IUI-AMAX-LED8 8 Zone LED Keypad
This keypad operates with the AMAX panel 2000 / AMAX panel 2000 EN control panel. It
provides indications for up to eight zones. The AMAX panel 2000 / AMAX panel 2000 EN
support a maxmium of two keypad. To use the two keypads at the same time, jumper must be
set to avoid address confliction.
–
Jumper off = address 1
–
Jumper short = address 2
8.6.8
IUI-AMAX-LCD8 8 Zone LCD Keypad
This keypad operates with the AMAX panel 2000 / AMAX panel 2000 EN control panel. This
keypad has a fixed icon display and provides indications for up to eight zone.