34
en | Fault and Tamper Description
AMAX panel 2000 / AMAX panel 2000 EN
F.01U.241.127 | V4 | 2011.12
Installation Manual
Bosch Sicherheitssysteme GmbH
4.
When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault.
5.3.2
Warning Device 1 Short
Condition:
Warning Device output is shorted.
Restore:
Warning Device output short is removed and fault is reset.
Supervise:
1.
Monitor the voltage by MPU.
2.
Report the siren fault to the configured destination programmed on location 140.
3.
Slow flash FAULT indicator (refer to the detailed description in chapter keypad
indicators)
4.
When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault.
5.3.3
Warning Device 2 Disconnected
Condition:
Warning Device is disconnected.
Restore:
Supervise:
1.
Monitor the voltage by MPU.
2.
Report the siren fault to the configured destination programmed on location 140.
3.
Slow flash FAULT indicator (refer to the detailed description in chapter keypad
indicators)
4.
When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault
5.3.4
Warning Device 2 Short
Condition:
Warning Device output is shorted.
Restore:
Warning Device output short is removed and fault is reset.
Supervise:
1.
Monitor the voltage by MPU.
2.
Report the siren fault to the configured destination programmed on location 140.
3.
Slow flash FAULT indicator (refer to the detailed description in chapter keypad
indicators)
4.
When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault
5.4
Telephone Line Fault
Condition:
Telephone line is broken or disconnected.
Restore:
Telephone line is restored or connected and fault is reset.
Supervise:
1.
Monitor the telephone line by MPU all the time when the telephone is idle.
2.
Report the telephone line fault to the configured destination programmed on location
140.