To delete a Remote Radio User Code:
1.
Enter your Installer Code + 956 and press [#] . Two beeps sound and the STAY and AWAY
indicators flash.
2.
Enter the number of the code (9 - 16) you want to change and press [#] . Two beeps
sound and the corresponding zone indicator lights.
3.
Press [*] to delete the User Code. Two beeps sound and the STAY and AWAY indicators
are extinguished.
4.
Repeat this procedure to delete other Remote Radio User Codes.
6.18
Change Domestic Phone Number
When the control panel is set up for domestic dialing, this function allows the installer to view
and program the telephone numbers that the system calls if an alarm occurs. Refer to
Section 7.5 Domestic Dialing, page 50 for more information.
To change domestic phone number:
1.
Enter the installer Code and press [957]. Two beeps sound and the STAY and AWAY
indicators flash.
2.
Enter the phone number. Each digit appears as you enter it.
3.
Press [#] to exit from this mode.
Example
If you want to program telephone number 9672 1777, enter Installer CODE + [9 5 7][#][9 6 7
2 1 7 7 7][#]
You can cancel the domestic dialing function at any time. Such as you moved to other
placesand do not want the system to dial your working phone number or mobile number any
more.
To disable domestic dialing:
Enter the installer Code and press [957], then set the first number as 15.
6.19
Enter Programming Mode
This function allows installer code holders to access the programming mode. Enter the
installer code + 958 and press [#] .
Two beeps sound and both the STAY and the AWAY indicators flash simultaneously to indicate
that you have into entered installer’s programming mode.
Once you enter into installer’s programming mode, you are automatially positioned at location
000.
6.20
Command 959 – Exit from installer’s programming mode
without saving the programming data
This command exits from the installer’s programming mode without saving the programming
data.
You can exit from installer’s programming mode from any location. No data will be saved when
this command is performed.
Exit from Installer’s programming mode without saving the programmed data.
Enter [9 5 9 #] under installer’s programming mode. Two beeps sound and system returns