Installation
5
Owner's Responsibilities
1. Oven(s) are uncrated, stacked (if applies) and
put in place.
NOTE: Refer to Leg Attachment and Stacking
information provided.
2. The owner/operator must have the following
plumbing and electrical requirements met and
installed.
NOTE: Refer to the Utility Connection inforĆ
mation provided.
WARNING!!
Improper installation, adjustment, alterĆ
ation service or maintenance can cause
property damage, injury or death. Read
the installation, operation and mainteĆ
nance instruction thoroughly before inĆ
stalling or servicing this equipment.
PLUMBING
Water
Building Water Pressure (min/max)
40 PSI min/50 PSI max
Cold Water Connection
3/4" Hose Fitting, 3/8" ID hose minimum
Hot Water Connection*
3/4" Hose Fitting*, 3/8" ID hose minimum
Pressure Regulator Setting
35 PSI Preset
Drainage
Atmospheric Vented Drain
Drain Connection
2" Copper
Avg Water Drain Temp.
122
_
F (50
_
C)
ELECTRICAL
Electrical*
18.4kw
Amp/Line (max)
Volt
3 Phase
1 Phase
208
52
89
240
45
77
480
23
N/A
By Mode
Steam
18.5kw
y
Hot Air
18.5kw
Combi
18.5kw
Blower Motor
.5 hp / 0.5 kw
*Not applicable with COSĆ8EDS, BCSĆ8DS and CNVĆ8E