Installation
11
Stacking
STACKING
1. Install 6" (15 cm) legs or casters on the bottom
unit. If casters are used, the casters with
brakes must be located on the front of the
oven.
2. Remove the three screws from the top of the
bottom unit.
3. Lift and mount the upper unit onto the lower
unit. Flush the edges on all four sides. Remove
the side panel and body back of both units.
Remove the lower body back from the top
unit.
4. Bolt the upper and lower units together with
the .50Ć13 UNC bolts provided.
Rear of Units
Bolt through
holes closest
to oven center
Step 4
Remove
body back
Remove
lower body
back
Remove
louvered
panel and
save screws
Remove
body back
Step 3
Step 1
Do Not Remove
Body Top
Caster with brakes
Figure 8
PLUMBING
NOTE: When stacking a CNVĆ8E with a COSĆ8E,
COSĆ8EDS or BCSĆ8E the drains must not
be manifolded together.
NOTE: The installation plumber is responsible for
connections between units and connecĆ
tion to the drain. Use a 24" section on the
top unit Tee to raise the breather vent. This
will prevent overflow if both units are flushĆ
ing simultaneously.
1. Attach the rubber couplings (included) to the
drain outlet of both units.
2. Install 2" copper pipe (not included) to the
floor drain.
3. Install suitable tubing to the floor drain from
the drip pan outlet on the rear of the unit.
Breather vent
Plumber installed
connection 24" long
Rubber coupling
Plumber installed
connection
Plumber installed
connection to drain
Rubber coupling
Figure 9