Operation
14
Oven StartĆUp
STEAM MODE (if applicable)
NOTE: For direct steam units, skip steps 3-5.
1. Turn the mode selector switch to STEAM.
2. The green POWER Indicator lamp on the front
control panel lights.
3. The steam generator flushes and drain autoĆ
matically for 75 seconds if the unit has been off
for at least 5 hours.
4. The steam generator begins to fill. After two
minutes, the FILL indicator lamp on the front
control panel blinks. The convection blower
and POWER lamp turn off.
5. When the steam generator is filled to the propĆ
er level, the convection blower, interior lights
and POWER indicator lamp turn on.
6. Steam fills the cavity and is controlled by a
nonĆaccessible internal thermostat.
HOT AIR MODE (if applicable)
1. Turn the mode selector switch to Hot Air.
2. The green POWER Indicator lamp on the front
control panel lights.
3. Set the hot air thermostat to the desired temĆ
perature.
4. The thermostat lamp lights, indicating the cavĆ
ity temperature is below the desired set point.
5. When the cavity temperature reaches the deĆ
sired set point, the temperature indicator lamp
goes off. The convection blower continues to
run until the door is opened or the timer preset
time runs out.
COMBI MODE (if applicable)
NOTE: For direct steam units, skip steps 4-6.
1. Turn the mode selector switch to COMBI.
2. The green POWER indicator lamp on the front
control panel lights.
3. Set the Hot Air thermostat to the desired temĆ
perature.
4. The steam generator flushes and drain autoĆ
matically for 75 seconds if the unit has been off
for at least 5 hours.
5. The steam generator begins to fill. After two
minutes the FILL indicator lamp on the front
control panel blinks. The convection blower
and POWER lamp do not shut down.
6. When the steam generator comes up to a preĆ
determined temperature, the hot air thermoĆ
stat lamp illuminates, indicating the cavity
temperature is below the desired set point.
7. When the cavity temperature reaches the deĆ
sired set point, the temperature indicator lamp
goes off.
8. The steam and hot air burners toggle back
and forth responding to the thermostat set
points.