16
Graphic display terminal
Programming: Example of accessing a parameter
Accessing the acceleration ramp
Note:
• To select a parameter:
- Turn the navigation button to scroll vertically.
• To modify a parameter:
- Use the << and >> keys (F2 and F3) to scroll horizontally and select the digit to be modified (the selected digit changes to white
on a black background).
- Turn the navigation button to modify the digit.
• To cancel the modification:
- Press ESC.
• To save the modification:
- Press the navigation button (ENT).
RDY
Term
+0.00 Hz
REM
1 DRIVE MENU
1.1 SIMPLY START
1.2 MONITORING
1.3 SETTINGS
1.4 MOTOR CONTROL
1.5 INPUTS / OUTPUTS CFG
Code
<<
>>
T/K
ENT
ESC
RDY
Term
+0.00 Hz
REM
1.3 SETTINGS
Ramp increment:
01
Acceleration
9.51 s
Deceleration:
9.67 s
Acceleration 2:
12.58 s
Deceleration 2:
13.45 s
Code
<<
>>
T/K
ENT
ENT or
ESC
RDY
Term
+0.00 Hz
REM
Acceleration
9.
5
1 s
Min = 0.01 Max = 99.99
<<
>>
T/K