[1.7 APPLICATION FUNCT.]
(FUn-)
Torque limitation
There are two types of torque limitation:
• With a value that is fixed by a parameter
• With a value that is set by an analog input (AI, pulse or encoder)
If both types are enabled, the lowest value is taken into account. The two types of limitation can be configured or switched remotely using
a logic input or via the communication bus.
[Yes]
(YES)
LI
[Motoring torque lim]
(tLIM)
[Gen. torque lim]
(tLIG)
Torque
limitation via
parameter
[Torque limit. activ.] (tLA)
[No]
(nO)
[LI]
[Yes]
(YES)
LI
[AI.] (AI.)
[RP] (PI)
[Encoder] (PG)
Torque
limitation via
analog input,
RP or
Encoder
[Analog limit. act.] (tLC)
[No]
(nO)
[LI]
Lowest value
taken into account
Limitation
value
[Torque ref. assign.] (tAA)
[AI]