162
[1.7 APPLICATION FUNCT.]
(FUn-)
Code
Name/Description
Adjustment range
Factory setting
MLP-
•
[PARAM. SET SWITCHING]
CHA1
• [2 Parameter sets]
[No]
(nO)
nO
LI1
-
-
-
-
[No]
(nO)
: Function inactive.
-
[LI1]
(LI1)
:
:
-
[...]
(...)
: See the assignment conditions on page
109
.
Switching 2 parameter sets
CHA2
• [3 Parameter sets]
[No]
(nO)
nO
LI1
-
-
-
-
[No]
(nO)
: Function inactive.
-
[LI1]
(LI1)
:
:
-
[...]
(...)
: See the assignment conditions on page
109
.
Switching 3 parameter sets
Note: In order to obtain 3 parameter sets,
[2 Parameter sets]
must also be configured.
• [PARAMETER SELECTION]
The parameter can only be accessed on the graphic display terminal if
[2 Parameter sets]
is not
[No]
.
Making an entry in this parameter opens a window containing all the adjustment parameters that can be
accessed.
Select 1 to 15 parameters using ENT (a tick then appears next to the parameter). Parameter(s) can also be
deselected using ENT.
Example:
PS1-
• [SET 1]
The parameter can be accessed if one or more parameters have been selected in
[PARAMETER
SELECTION]
.
Making an entry in this parameter opens a settings window containing the selected parameters in the order
in which they were selected.
With the graphic display terminal:
With the integrated display terminal:
Proceed as in the Settings menu using the parameters that appear.
PARAMETER SELECTION
1.3 SETTINGS
Ramp increment
- - - - - - - - -
- - - - - - - - -
- - - - - - - - -
RDY
Term
+0.00 Hz
REM
SET1
Acceleration : 9.51 s
Deceleration : 9.67 s
Acceleration 2 : 12.58 s
Deceleration 2 : 13.45 s
Begin Acc round : 2.3 s
Code
T/K
ENT
RDY
Term
+0.00 Hz
REM
Acceleration
9.51 s
Min = 0.1 Max = 999.9
<<
>>
T/K
Summary of Contents for ER40-G