FlightHawk RF Test Set
B-6
When the test is complete, the result is displayed on the screen. If the test
passes, the system’s VSWR is below the threshold set for the test. If the test fails,
the VSWR is above the threshold set for the test. See
.
Figure 7 VSWR Test Results Screen
When the results are displayed, the technician is given two options.
Detailed Results - tapping the Detailed Results button will open the
FlightHawk-AV’s measurement display. The trace created during the
test will appear in the display and the technician will be able to see the
exact values returned during the test. See
New Test - tapping the New Test button will open a new test selection
screen. See
.
Note:
If a FAIL flag is noted, select Detailed Results and verify the out-
of-limit VSWR reading is contained within the Operational Frequency
Band. Set markers if necessary to identify Operational Frequency band,
see
for details on adding markers. A trace that
fails outside the Operational Frequency band should not be considered
a valid failure and disregarded unless explicitly directed by your official
maintenance manual or diagnostic procedure.
!"#$
""%$
%$