FlightHawk RF Test Set
68
Export Session File
When you connect to a Bird Power Sensor with the Bird RF Meter App a Serial
Number Specific Session File is created. You can also save your settings as the
default settings for your power sensor type in a Default Preset or Preset. All of
these file types can be exported from the Bird RF Meter App for use on other
Android devices.
1.
Tap the menu overflow icon.
2.
ap Session List.
3.
Press the session file for the device setup up above until the save menu is
displayed.
4.
Tap Export.
5.
Rename the file if desired then click OK.
Exported Session Files are saved on the internal memory of the Android device
and can them be transfer to a PC or another Android device.
Typical Path: SDCARD>Bird RF Meter>Sessions.
Import Session File
If you wish to import one or more Session Files onto an Android device you must
first copy the files onto the Android device into the Bird RF Meter folder.
1.
Transfer the desired Session Files into the following folder on the
destination Android device: SDCARD>Bird RF Meter>Sessions
2.
Tap the menu overflow icon.
3.
Tap Session List.
4.
Tap the menu overflow icon in the Session List.
5.
Tap Import Session.
6.
Select the files for import in the Dialog Box (if no files are visible, repeat
step 1).
7.
Tap OK
Load a Session File
1.
Connect a sensor.
2.
Tap the Sensor Operation Menu .
3.
Tap load preset.
4.