RF Power Measurement
69
Delete Session File
1.
Open the Session List.
2.
Press the Session File you wish to delete until the until the delete menu is
displayed.
3.
Tap Delete.
Measurement Descriptions
Average Power
Average power is a measure of the equivalent “heating” power of a signal, as
measured with a calorimeter. It measures the total RF power in the system, and
does not depend on number of carriers or modulation scheme. The WPS is a
broadband sensor that measures power across its entire frequency range. Its
diodes operate in their ‘square law’ region so that the detector output is directly
proportional to the average power, without any additional error correction.
Average power is the most important measurement of any transmission system
since the average power is normally specified on the operating license. It is also
valuable as a maintenance tool, showing overall system health, and for
calibration.
Figure 60 Average and Peak Envelope Power - Square Wave Signal
Average Power
Peak Envelope Power
0 W
50 W
100 W