Analog inputs
Number
2 analog inputs, 0 … 20 mA / 0 ... 10 V switchable (X10/X13)
Input characteristics
Up to 20 mA U < 5 V in case of short circuit, max. 40 mA
Resolution
10 bit (accuracy 8 bit)
Connection technique
Standing front wiring for 3.81 terminal strips (not part of the standard deli-
very)
CAN interfaces
Number and type of inter-
faces
1 CAN interface for (X20) contact line communications / SC_CAN (X3);
1 SC_CAN monitoring interface with standard signals
Connection technique
Standing front wiring for 3.81 terminal strips (not part of the standard deli-
very)
Operating and display elements
Display elements
Interface (X11) for 5-place, 7-segment display with IR receiver diode for
remote control