USER MANUAL 1.10 | DC1000 DIALOG-CONTROLLER
Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com
2VF100108FE04.docx | DC1000_HB_en_2D0982010ZD00.docx
69
This display appears if an error has occurred when the
PLC program is executed, i.e. during program run.
The following error statuses can be displayed:
ACCESS_VIOLATION
RTSEXCPT_WATCHDOG
RTSEXCPT_DIVIDEBYZERO
Standard procedure in case of an error:
Saving all relevant data is an important factor for error
analysis. The diagnostic information generated by the de-
vice should be saved for this reason.
“Save Diag”
is used to store the relevant diagnostic data
for example on a plugged-in USB stick. After such an error
the Controller must be rebooted. This takes place after
data backup, using the
“Reboot”
button.
Note:
The diagnostic data must definitely be saved
prior to re-
booting
because only at this time can all the important
data be saved!
EXCEPTION
Major exceptional
errors