Universal Wireless Device System
VectorBRIDGE
Number of Zones on BPI
The following table shows the BPI events (
BPI EVENTS
columns) that will
signal the Interface Zone Alarms (
ALARM
column) and Tamper events (
TAMPER
column) when the BPI Interfacing terminal board is connected to the bus of
Omnia, Omnia840 or Academy40.
The numbers in the
IN.
EXP.
column show the Input Expanders that will be
simulated by the Interface, in accordance with the programmed
Number of
Zones on BPI
(
NUM.
column). The numbers in brackets in the
BPI Events
column show the Control panel events that will signal Interface Zone Alarms
and Tamper events, in accordance with the disabled/enabled status
of the
Auxiliary Signals on BPI
option.
NUM.
IN. EXP.
ALARM
BPI EVENTS
TAMPER
BPI EVENTS
31*
16
8
01/02
Zone 01
Alarm Wireless Zone 01
(Alarm on zone 17/21)
Zone 01
Tamper Wireless Zone 01
(Tamper on zone 17/21)
â
â
â
â
â
â
â
â
02/03
Zone 08
Alarm Wireless Zone 08
(Alarm on zone 24/28)
Zone 08
Tamper Wireless Zone 08
(Tamper on zone 24/28)
03/04
Zone 09
Alarm Wireless Zone 09
(Alarm on zone 25/29)
Zone 09
Tamper Wireless Zone 09
(Tamper on zone 25/29)
â
â
â
â
â
â
â
â
04/05
Zone 16
Alarm Wireless Zone 16
(Alarm on zone 32/36)
Zone 16
Tamper Wireless Zone 16
(Tamper on zone 32/36)
05/06
06/07
Zone 17
Alarm Wireless Zone 17
(Alarm on zone 33/37)
Zone 17
Tamper Wireless Zone 17
(Tamper on zone 33/37)
â
â
â
â
â
â
â
â
07/08
08/09
Zone 31
Alarm Wireless Zone 31
(Alarm on zone 47/51)
Zone 31
Tamper Wireless Zone 31
(Tamper on zone 47/51)
Program the number of zones (8, 16, 31*) the Interface must simulate on the BPI
bus, as follows.
1 Use
9
9
or
0
0
to scroll the menu. Select the
Num.Zones
on BPI
option, then press
E
E
to continue, or press
e
e
to exit programming.
Select
Select
_
_
Option
Option
___
___
Num.Zones
Num.Zones
_
_
on
on
_
_
BPI
BPI
2 Use
9
9
or
0
0
to scroll for the required number of zones
to be simulated on the BPI bus. Record the selected
value in Table A3 in the Programming Sheets.
Num.Zones
Num.Zones
_
_
on
on
_
_
BPI
BPI
16
16
______________
______________
3 Press
E
E
to confirm the selected value, or press
e
e
and go back to Step 1.
*)
Expandable panels with up 40 zones, such as: Omnia840 and Academy40 support up to 20
Wireless Sensors if the
Auxiliary Signals on BPI
option is enabled, or 24 Wireless Sensors if
this option is disabled (refer to “Auxiliary Signals on BPI”).