70
Universal Wireless Device System
VectorBRIDGE
Partitioning
The operating mode of this Output depends on the status of the
Use MEM. x
TER. K
option
(refer to “Use MEM. for Terminal K” in the “PROGRAMMING
THE INTERFACE” section):
Ø
if the
Use MEM x Ter. K
option is DISABLED (at default), Output KS will acti-
vate for 2 seconds when Partitioning by Wireless Key is requested;
Ø
If the
Use MEM x Ter. K
option is ENABLED, Output KS will activate for 2
seconds when Partitioning by Wireless Key is requested, and the
MEM
Input is
open (floating).
Connect this Output to a Control panel Input—programmed to perform Parti-
tioning operations.
Panic
This Output will activate for 2 seconds when Panic requests are made by Wire-
less Key.
Connect this Output to a Control panel Input, or to a telephone device Input —
(Telephone Dialler, Telephone Communicator, etc.)—programmed to communi-
cate “Panic” requests.
Alarm Outputs
This Output will activate when one of its assigned zones goes into Alarm
status, and will return to Standby status when Standby status is restored on all
of its assigned zones (refer to “Zone Mapping” in the “PROGRAMMING THE
INTERFACE” section).
Connect these Outputs to a Control panel Input Lines.
Connecting the Receiver
Connect the Receiver terminal
25
to the Interface terminal
5
(as per Figure
6
page 70).
+
Use Shielded cable for the connection: connect one end of the shield to termi-
nal
BLK
on the Interface, and leave the other end free. Do not use more than 50
metres total wire length.
KH
A1 ... A8
KS
GRN
YEL
BLK
RED
GRN
YEL
BLK
RED
In
te
rf
a
c
e
R
e
c
e
iv
e
r
Figure 6
Connecting the Receiver to the Interface