68
Universal Wireless Device System
VectorBRIDGE
n
n
Inputs
Memory Reset and Scrolling
Input for viewing and deleting the Interface memory.
Ø
Terminal connected to ground for
LESS
than 3 seconds > Scroll memory.
Ø
Terminal connected to ground for
MORE
than 3 seconds > Reset memory.
This Input can be connected to a Control Panel Output that connects to Ground
for at least 3 seconds when the Control panel is armed. In this way, the Interface
Memory will be deleted automatically each time the Control Panel is armed.
+
The R/S Input operates in the same way as the
R/S
button (
2
).
Enable Memory
When this Input is connected to Ground the Interface will record the alarms
generated by Wireless Sensors.
+
Other Events such as: Tamper, Low Battery, Missing and Jamming will be re-
corded, regardless of the Enabled/Disabled status of the MEM Input.
Connect this Input to a Control panel Output that is connected to Ground during
armed status. In this way, the Interface will record alarms generated by Wire-
less Sensors only
when the Control panel is armed.
+
The MEM Input can also control the operating mode of Outputs KA, KD and KS,
in accordance with the status of the
Use MEM xTer. K
option (refer to “Use
MEM for Terminal K” in the “PROGRAMMING THE INTERFACE” section).
n
n
Outputs
+
It is possible to program the Standby status of the Outputs described in this
section (refer to “Standby for Outs” in the “PROGRAMMING THE INTERFACE”
section):
OUTPUT STANDBY
OUTPUT STANDBY
ACTIVE OUTPUT
Normally Closed
Terminal Closed to Ground
Terminal Open (floating)
Normally Open
Terminal Open (floating)
Terminal Closed to Ground
Tamper
This Output will be activated by Tamper on Wireless Sensors, the Receiver or
on the Interface. Standby status will be restored when Tamper signalling stops.
Tamper on the Receiver is generated when the Snatch switch
20
is activated
(Receiver snatched from the wall), or when the Receiver Tamper switch
21
is
activated (Receiver box opened). Interface Tamper is generated when the Inter-
face Tamper switch
8
is activated (Interface box opened)).
+
The Interface Tamper switch
8
can be disabled by connecting jumper
7
.
Connect the
TMP
Output to the end of the Control panel Tamper line. If the Control
panel Tamper line is balanced, connect the Balanced Resistor to this Output.
R/S
MEM
TMP
Summary of Contents for VectorBRIDGE
Page 95: ......