–4–
M-3410A Intertie/Generator Protection Relay
PROTECTIVE FUNCTIONS (
PROTECTIVE FUNCTIONS (
PROTECTIVE FUNCTIONS (
PROTECTIVE FUNCTIONS (
PROTECTIVE FUNCTIONS (cont
cont
cont
cont
cont.)
.)
.)
.)
.)
Device
Device
Device
Device
Device
Setpoint
Setpoint
Setpoint
Setpoint
Setpoint
Number
Number
Number
Number
Number
Function
Function
Function
Function
Function
Ranges
Ranges
Ranges
Ranges
Ranges
Increment
Increment
Increment
Increment
Increment
Accuracy
Accuracy
Accuracy
Accuracy
Accuracy
Loss-of-Field (dual-zone offset-mho characteristic)
Circle Diameter #1, #2
0.01 to 3.00
0.01 PU
0.01 PU or
5%**
Offset #1, #2
–2.0 to 2.0
0.01 PU
0.01 PU or
5%**
Time Delay #1, #2
1 to 8160 Cycles
1 Cycle
2 Cycles
Voltage Control
4 to 100%*
0.1%
0.5 V
or
0.5%
(positive sequence)
Directional Element
Fixed at –13°
—
—
* Of nominal voltage.
** Accuracy applies for a nominal current range of 2.5 A to 6 A (5 A CT) or 0.5 A to 1.5 A (1 A CT).
Negative Sequence Overcurrent
Negative Sequence Overcurrent
Negative Sequence Overcurrent
Negative Sequence Overcurrent
Negative Sequence Overcurrent
Definite Time
Pickup
3% to 300%*
1%
0.1 A or
0.5%**
(
0.02 A or
0.5%)
Time Delay
1 to 8160 Cycles
1 Cycle
2 Cycles
Inverse Time
Pickup
3% to 100%*
0.1%
0.1 A or
3%**
(
0.02 A or
3%)
Characteristic Curves
Definite Time/Inverse Time/Very Inverse/Extremely Inverse/IEC/I
2
2
t=K
Time Dial Setting
0.5 to 11.0
0.1
0.05 to 1.1 (IEC)
0.01
3 Cycles or
10%**
1 to 95 (
I
2
2
t=K)
1
For
I
2
2
t=K Curve Only
Definite Maximum
Time to Trip
600 to 65,500 Cycles
1 Cycle
3 Cycles or
10%**
Reset Time (Linear)
4 minutes
(from threshold of trip)
* Of nominal current for currents less than 14 A (2.8 A).
** Accuracy applies for a nominal current range of 2.5 A to 6 A (5 A CT) or 0.5 A to 1.5 A (1 A CT), and for a
pickup of >5%.
Negative Sequence Overvoltage
Negative Sequence Overvoltage
Negative Sequence Overvoltage
Negative Sequence Overvoltage
Negative Sequence Overvoltage
Pickup #1, #2
4 to 100%*
0.1%
0.5 V
or
0.5%
Time Delay #1, #2
1 to 8160 Cycles
1 Cycle
2 Cycles
* Of nominal voltage.
Inverse Time Residual Overcurrent
Inverse Time Residual Overcurrent
Inverse Time Residual Overcurrent
Inverse Time Residual Overcurrent
Inverse Time Residual Overcurrent
Pickup
0.50 to 6.00 A
0.1 A
0.1 A or
3%
(0.10 to 1.20 A)
(
0.02 A or
3%)
Characteristic Curves
Definite Time/Inverse Time/Very Inverse/Extremely Inverse/IEC
Time Dial
Standard Curves #1–#4
0.5 to 11.0
0.1
3 Cycles or
10%
IEC Curves #1–#4
0.05 to 1.10
0.01
Values in parentheses apply to 1 A CT secondary rating.
47
46
51N
27
40
Summary of Contents for Syncrocloser M-3410A
Page 1: ...Instruction Book M 3410A Intertie Generator Protection Relay ...
Page 39: ...xiv M 3410A Instruction Book This Page Left Intentionally Blank ...
Page 71: ...M 3410A Instruction Book 2 28 This Page Left Intentionally Blank ...
Page 121: ...M 3410A Instruction Book 3 50 This Page Left Intentionally Blank ...
Page 161: ...1 3 A B C M 3410A Instruction Book 4 40 This Page Left Intentionally Blank ...
Page 223: ...M 3410A Instruction Book F 2 This Page Left Intentionally Blank ...