4–23
Operation and Interface – 4
Connect
When
Connect
is displayed (upper right) the
M-3410A is disconnected (physically by RS-232
cable/cradle and/or communications are not
established) from the handheld.
Selecting
Connect
initiates the
Connect
dialog
screen (Figure 4-35). The user is prompted to select
the
Baud Rate
,
Parity
and
Stop Bits
and then
input the individual M-3410A
Address
(1 to 247)
and
Communication Access Code
(0 to 9999). A
Communication Access Code
of 9999 is the default
value.
M-3811A
Connect...
OK
Cancel
Connect
Baud Rate:
9600
Parity:
None
Stopbits:
1
Address: 1
(1 to 247)
Access Code: 9999
Figure 4-35
M-3811A IPScom
®
for Palm
OS
®
Connect Dialog Screen
When settings and data have been input the user
can select either
OK
to
Connect
or
Cancel
to
return to the
Main Screen
.
If
OK
is selected, then the handheld establishes
communication with the M-3410A and determines if
User Access Security
has been invoked.
If an incorrect Communication Access code is
entered, then the handheld will respond with an
error message.
Security
Invalid communication
access code
OK
Figure 4-36
M-3811A IPScom for Palm OS
Invalid Access Code Error Screen
If the default User Access Code present on the
relay is 9999 (default), then the relay will respond
with a Security Dialog Screen (Figure 4-37) that
indicates that Security Level 3 (all read and write
features) access has been granted.
Security
Access level granted: 3
OK
Figure 4-37
M-3811A IPScom for Palm OS
User Access Level Granted
If User Access Security has been invoked on the
relay, then the relay will prompt the user for a User
Access Code. The user must enter a User Access
Code, then select
OK
. The relay will respond with
the Security Dialog Screen indicating the level of
access that has been granted to the user.
Security
Access level code: 9999
OK
Cancel
Figure 4-38
M-3811A IPScom for Palm OS
User Access Level Code
For Communication and User Access Level Code
Privileges, see Table 4-1 (page 4–12).
Summary of Contents for Syncrocloser M-3410A
Page 1: ...Instruction Book M 3410A Intertie Generator Protection Relay ...
Page 39: ...xiv M 3410A Instruction Book This Page Left Intentionally Blank ...
Page 71: ...M 3410A Instruction Book 2 28 This Page Left Intentionally Blank ...
Page 121: ...M 3410A Instruction Book 3 50 This Page Left Intentionally Blank ...
Page 161: ...1 3 A B C M 3410A Instruction Book 4 40 This Page Left Intentionally Blank ...
Page 223: ...M 3410A Instruction Book F 2 This Page Left Intentionally Blank ...