M-3410A Instruction Book
4–6
Relay
Setup
Monitor
Event Recorder
Oscillograph
Write File to Relay
Read Data From Relay
Unit Properties
Setup Relay
Setpoints
Set Date/Time
The
Setup
submenu provides three commands:
Setup Relay
,
Setpoints
, and
Set Date/Time
. The
Setup Relay
command displays the Setup Relay
dialog box, allowing the input of the pertinent
information regarding the system on which the
protective relay is applied (see Section 3.1,
Relay
Configuration
, Relay System Setup).
Relay Menu
Relay
Setup
Monitor
Event Recorder
Oscillograph
Write File to Relay
Read Data From Relay
Unit Properties
The
Relay
menu provides access to the windows
used to set, monitor, or interrogate the relay. Four
submenus are provided:
Setup, Monitor, Event
Recorder
and
Oscillograph,
as well as three
commands,
Write File to Relay
,
Read Data From
Relay,
and
Unit Properties
.
Setup Relay
Nominal Frequency:
60 Hz50 Hz C.T. Secondary Rating:
5A
1A
Nominal Voltage: 120
Nominal Current: 5
50 V
0.50 A
500 V
6.00 A
Delta-Y Transform
Enable
Disable
Normal
Latching
Normal
Latching
Output Contact
Mode
1
2
1
2
Open
Close
Open
Close
Input Active State:
VT Configuration:
Line to Ground
Line to Line Line-Ground to Line-Line
User Logo:
Save
Cancel
OK LED Flash:
Enable
Disable
Relay Seal-In Time:
OUT1: 5
OUT2: 5
8160
Cycles
2
Cycles
V.T. Phase Ratio: 1
C.T. Phase Ratio: 1
V.T.
Sync
/V
g
Ratio: 1
:1
:1
:1
1.0
1
1.0
6550.0
65500
6550.0
59/27 Mag. Select:
Phase Rotation:
RMS
ABC
DFT
ACB
Output Relay:
Deenergize to Actuate (Failsafe):
Energize to Actuate:
1
2
Figure 4-4
M-3810A IPScom
®
for Windows™ Setup Relay Dialog Box
Path:
Relay menu / Setup submenu / Setup Relay command
COMMAND BUTTONS
Save
When connected to a protection system, sends the currently displayed information to the unit.
Otherwise, saves the currently displayed information.
Cancel
Returns you to the IPScom main window; any changes to the displayed information are lost.
Q
Q
Q
Q
Q
NOTE:
Checking the inputs for the Active Input Open parameter designates the “operated” state established by
an
opening rather than a closing external contact.
Summary of Contents for Syncrocloser M-3410A
Page 1: ...Instruction Book M 3410A Intertie Generator Protection Relay ...
Page 39: ...xiv M 3410A Instruction Book This Page Left Intentionally Blank ...
Page 71: ...M 3410A Instruction Book 2 28 This Page Left Intentionally Blank ...
Page 121: ...M 3410A Instruction Book 3 50 This Page Left Intentionally Blank ...
Page 161: ...1 3 A B C M 3410A Instruction Book 4 40 This Page Left Intentionally Blank ...
Page 223: ...M 3410A Instruction Book F 2 This Page Left Intentionally Blank ...