Sample Installation Scripts
112768 Rev. B
D-3
You must press the <Return> key after entering one of the above responses.
Press <Return> to Continue, q<Return> to Quit:
-------------------------------------------------------------------------------
Preliminary Information You Need to Know
----------------------------------------
Before you begin this procedure, you should gather the network
information listed below:
You Need to Know This Information: For Example:
---------------------------------- ------------
Type of Net Module connecting the router's DENM
IP network interface to the Site Manager.
Slot number where the Net Module resides. 2
Module number where the Net Module resides. 1
Communication type and connector number Ethernet 10bT1
IP address of initial IP network interface 192.32.10.189
Subnet mask of initial IP network interface 255.255.255.0
IP address of Site Manager workstation 192.32.10.200
Do you wish to continue? (y/n)[y]:
-------------------------------------------------------------------------------
Step 1. Specify the slot number where the Net Module resides.
Slot Menu for Net Module
-------------------------
Slot Module Net Module Processor Module
---- ------ ---------- ----------------
11 1 Empty 5380
11 2 Empty 5380
11 3 IQE 5380
Slot 11 selected.
Enter the module number [1]: 3
-------------------------------------------------------------------------------
Step 2. Specify the Net Module and network interface information for
the initial IP connection to the Site Manager.