Initializing and Setting Up the Routers
112768 Rev. B
3-29
Clearing a Slot
You will need to clear a slot if you want to install a different model router module
or other type of System 5000 module from the previously installed module. For
example, Figure 3-22 shows the Slot Selection Menu indicating a Model 5380
Ethernet Router has been removed from slot 8 in the chassis. In order to install a
different module into slot 8, the configuration information stored in the
Supervisory Module for the slot must be cleared.
Figure 3-22.
Slot Selection Menu Showing Removed Module
To clear the configuration information for a slot:
1.
Press s on the Slot Selection Menu.
The Supervisory Module Main Menu is displayed (see Figure 3-23).
Model 5000 Slot Selection Menu 11/08/96, 12:23:49PM
Slot Status Module Description
1 On-Line 5308-AF Ethernet Host
2 On-Line 5310 Ethernet NMM
3
4 Booting 5390 Comm Server
5
6 On-Line 5378-F Ethernet Host
7 On-Line 5308P Ethernet Host
8 (Removed) 5380 Ethernet Router
9 On-Line 5505P Token Ring Host
10 On-Line 5575-F Token Ring Host
11 On-Line 5380 Ethernet Router
12 On-Line 5580 Token Ring Router
13
14 On-Line 58000 10/100 Ethernet Switch
c - Connect to slot [Press CTRL-T to break connection]
s - Select Supervisory Module main menu r - Reset module
Enter selection: s