9. Service Mode
Remaining run time
Time left before the lamp must be replaced. Using the lamp longer than the maximum run
time may damage the projector
Number of strikes
Total times the lamp is started up
Z-axis
Indication to adjust the Z-axis of the lamp, for more information see ’Re-adjusting the lamp
position in the lamp casing’ in chapter ’Installation Guidelines’
Table 9-1
Lamp Information
Following Lamp Settings can be changed:
•
Constant Light Output
•
(Lamp) Mode
How to Start Up the Lamp Menu?
1. Push the cursor key
↑
or
↓
to highlight
Lamp.
2. Press
ENTER
to select.
The Lamp Menu will be displayed. (menu 9-14)
SERVICE
IDENTIFICATION
CHANGE PASSWORD
CHANGE PROJ. ADDRESS
CHANGE BAUDRATE PC
LAMP
MORE ...
Select with
↑
or
↓
then <ENTER>
<EXIT> to return
Menu 9-13
LAMP
CONSTANT LIGHT OUTPUT [ON]
LINKED CLO [SLAVE]
MODE [NORMAL]
TARGET CLO LUMENS: 10000
LAMP RUNTIME WARNING [MAXIMUM]
_________________________________
Serial number :
003706
Article number :
R9840740
Run time :
140 hours
Remaining run time :
1360
hours
Number of strikes :
160
Z-axis :
100 units
_________________________________
Select with
↑
or
↓
<ENTER> to toggle
<EXIT> to return
Menu 9-14
9.8.2
Constant Light Output (CLO)
What can be done?
Projectors in a multichannel setup may have different Lamp Runtimes, this will result in a difference in light output between the
projectors.
Within this menu it is possible to track and maintain the brightness levels of the projectors, the projectors will deliver a Constant Light
Output = CLO.
In a multichannel setup (max 14.) it is possible to link the CLO–values of all projectors, this is done by means of a master–slave
projector setup. One projector will act as master, all slave–projectors will track and maintain the CLO setting of this master–projector.
In a Linked CLO and/or Dynacolor™ setup a maximum of 14 projectors can be linked, all projectors must have
a different projector address between 0 and 13 and all projectors must have the same baudrate.
The CLO setting of one projector must be in the master position, all others must be in the slave position.
In a setup with one single projector, CLO will not work at all, when this projector is set in the slave position.
How to Connect the Master–Slave Projectors?
1. Connect a RS232 Terminator (Order number
Z3498823
) to the ’RS232 In’ Input of the first projector in the chain.
2. Connect the RS232 Output of the first projector in the chain to the RS232 Input of the next projector.
3. Continue this daisy chain connection to connect all projectors in the set up.
How to Change the Constant Light Output Setting?
1. Push the cursor key
↑
or
↓
to highlight
Constant Light Output.
144
R5976780 GALAXY SXGA+ SERIES 14/10/2005
Summary of Contents for Galaxy 12 High Brightness+ R9040370
Page 4: ......
Page 14: ...2 Packaging and Dimensions 10 R5976780 GALAXY SXGA SERIES 14 10 2005...
Page 44: ...4 Connections 40 R5976780 GALAXY SXGA SERIES 14 10 2005...
Page 51: ...5 Getting Started Image 5 6 RCU to IR Sensors R5976780 GALAXY SXGA SERIES 14 10 2005 47...
Page 60: ...6 Special Features 56 R5976780 GALAXY SXGA SERIES 14 10 2005...
Page 132: ...7 Random Access 128 R5976780 GALAXY SXGA SERIES 14 10 2005...
Page 166: ...9 Service Mode 162 R5976780 GALAXY SXGA SERIES 14 10 2005...
Page 168: ...10 Standard Source Files 164 R5976780 GALAXY SXGA SERIES 14 10 2005...