8.6 Fault Diagnostics — OBI
Troubleshooting the Controller and connected I/O devices is
easy using the Onboard Interface . Any event that causes a
safety output to turn OFF or stay OFF (either for fault or input
stop events) will be immediately detected and displayed on the
Controller’s display . Further information about current and past
faults can be accessed using the Fault Diagnostics menu . To
get to the Fault Diagnostics menu, press OK from the Run mode
menu . Select Fault Diagnostics and press OK .
Figure 8-3. Select Fault Diagnostics — OBI
The Diagnostics menu provides three choices: view fault
conditions that currently exist, view faults that have been stored
in the fault log, and clear the fault log .
8.6.1 View Current Faults
To view current fault conditions, select View Current Faults
using the up/down arrow buttons and press OK .
Figure 8-4. View current faults — OBI
The screen shows the fault conditions that currently exist, one
at a time . Use the left/right arrow keys to view all the faults .
(Shortcut: To view current faults when the Run mode screen is
displayed, simply press OK three times .)
• The top line of the Current Fault menu indicates which device
has the fault .
• The second and third lines provide a brief description of the
fault .
• The fourth line provides a suggestion for correcting the fault .
• The fifth line provides the fault code . Use the fault code and
information in Section 8 .x to obtain more information about
the fault and additional suggestions for correcting it .
Use the left/right arrow (< and >) buttons to access fault
information for all faulty devices .
Figure 8-5. Current Fault screens — OBI
Arrowhead designates location of additional fault screens
Device Name
Fault
Description
Suggested
Remedy
Fault Code