54
P/N 133487
Banner Engineering Corp.
•
Minneapolis, U .S .A .
www .bannerengineering .com • Tel: 763 .544 .3164
SC22-3 Safety Controller
Instruction Manual
Configuration — Onboard Interface
Map Outputs — This option is used to select which of the safety
output(s) the input controls . Any combination of 1, 2, or all 3
outputs may be selected,
but at least one must be selected.
All
safety devices, plus reset and ON/OFF non-safety devices must
be mapped to one or more safety outputs . Map mute enable
devices, mute sensors, and bypass sensors to a safety input
device .
• Select Map Outputs in the Input Properties menu, and press
OK .
• To map the input to an output, use the up/down arrows to
select the output, then press OK .
• A filled-in circle on the display indicates the input is mapped
to the corresponding output; an empty circle indicates the
input is not mapped to that output .
• To add or remove the input mapping, select the output and
press OK . When the input is mapped to the safety outputs
as desired, select Save and press OK .
• After the input is mapped to the safety outputs, the display
returns to the Input Properties menu .
Screen below shows device ES01 mapped to all three
safety outputs.
←
O
K
ES
C
→
Safety Input
(Section 5.5.1)
Non-Safety
Input
(Section 5.5.2)
←
O
K
ES
C
→
←
O
K
ES
C
→
M
ut
e
En
ab
le
Re
se
t
O
N/
O
FF
G
at
e
Sw
itc
h
O
pt
ic
al
Se
ns
or
E-
St
op
Sa
fe
ty
M
at
Pr
ot
ec
tiv
e
St
op
Tw
o-
Ha
nd
Co
nt
ro
l
En
ab
lin
g
De
vi
ce
Ro
pe
Pu
ll
ED
M
By
pa
ss
Sw
itc
h
M
ut
e
Se
ns
or
Add Input
(Section 5.5)
Add an Input continued
Select Reset Logic — To select automatic or manual reset
logic, select Reset Logic and press OK .
• Use the left/right arrows to select the desired reset logic
parameter and press OK .
• After setting the Reset Logic parameter, the display returns
to the Input Properties menu .
Save the Input Device Parameters — When all of the device’s
parameters have been set as desired, select < Done > and
press OK to save the parameters .
• The display will indicate the input parameters were saved .
Press OK to continue .
• The display returns to the Edit Inputs menu .