6.7.3 Events
PD Update Timeout
With special process data values, the device automatically
checks whether the values are updated in the time period
specified by the device. If an update timeout is triggered as
a result, this is output via the following diagnosis
messages:
Event
Code
Event
Type
Description
Device Status
0x1851
(6225)
Notifica-
tion
Process Data
Update
Timeout – for
information
purposes
only
0 – Device is
operating properly.
0x1852
(6226)
Warning
Multiple
Process Data
Update
Timeout – for
information
purposes
only
0 – Device is
operating properly.
Tab. 6-24: Process data information and configuration – Events
PD Profile Selection after change of variant
If the variant of the device is changed, the currently set
profile is retained.
In the case that the corresponding PD profile is not valid
for this variant, the default profile for the corresponding
variant is selected.
Event
Code
Event
Type
Description
Device Status
0x1850
(6224)
Notifica-
tion
Process data
profile
selection
cannot be
used –
default value
is used.
0 – Device is
operating properly.
Tab. 6-25: Process data information and configuration – Events
6
System Functions (continued)
6.7.4 Variant Dependence
The selection of the process data profile is variant-
dependent. A PD profile is assigned to each variant.
Device
Variant
Device ID
Possible PD variants
0x0001 (1)
LSSC
0x020404
(131100)
0x1E (30) Default
0x0002 (2)
ADSS
0x020405
(131101)
0x1F (31) Default
0x0003 (3)
CCM
0x020406
(131102)
0x0F (15) Default
Tab. 6-26: Process Data Information and Configuration – Variant
Dependency
PD Invalid
PD Inputs Invalid:
Input data (device-to-master) is marked as invalid if the
device status
(see section 6.1 on page 75) of the device
is
Failure
. In all other states, replacement values for the
data are output for which the content cannot be output
correctly.
PD Outputs Invalid:
If a master sends the process data without explicitly
marking the data as valid by means of
master command
,
the data is not used in the device. The device operates
only with the last valid data. A special behavior can,
however, be defined for various pieces of data (e.g., BNI
can configure the values collected in this state by means of
parameters).
BES M12EH1-L01C40B-S04G-L04 / BES M18EH1-L01C80B-S04G-L04
Inductive sensors
Summary of Contents for IO-Link BES M12EH1-L01C40B-S04G-L04
Page 2: ...www balluff com...
Page 3: ...BES M12EH1 L01C40B S04G L04 BES M18EH1 L01C80B S04G L04 IO Link Konfiguration deutsch...
Page 4: ...www balluff com...
Page 95: ...BES M12EH1 L01C40B S04G L04 BES M18EH1 L01C80B S04G L04 IO Link Configuration english...
Page 96: ...www balluff com...
Page 187: ......