64
english
5
Secondary Device Functions (continued)
Threshold Vibration
Threshold value for the detection of excessive vibrations.
Upper Threshold Temperature
Threshold value for the detection of excessive temperature.
Lower Threshold Temperature
Threshold value for the detection of temperature that is too
low.
State
The current status can be read under
State
.
Bit
Name
Description
0
Vibration
The vibrations are above the
threshold value.
1
Upper
Temperature
The temperature is above the
threshold value.
2
Lower
Temperature
The temperature is below the
threshold value.
3
Internal
Humidity
The humidity is too high.
Tab. 5-46: Extreme environment status – State
Time
Under
Time
, the summed time in seconds in which the
device was exposed to an extreme condition can be read
out.
5.10.5 Events
Event
Code
Event
Type
Description
Device
Status
0x8D13
(36115)
Warning
One or more
extreme conditions
present.
0 – Device is
operating
properly.
Tab. 5-47: Extreme environment status – Events
5.10.6 Variant Dependence
The functionality is available in all variants.
5.10.7 System Commands
Command Value Device Action
0x81 (129)
Application Reset
– Resets writable
parameters to the default value.
0x82 (130)
Reset Factory Settings
– Resets
writable parameters to the default
value.
0xA5 (165)
Maintenance Reset
– Resets the
value for
Time
and Flags.
Tab. 5-48: Extreme environment status – System Commands
For an overview of all System Commands, see section 3.5
BES M12EH1-L01C40B-S04G-L04 / BES M18EH1-L01C80B-S04G-L04
Inductive sensors
Summary of Contents for IO-Link BES M12EH1-L01C40B-S04G-L04
Page 2: ...www balluff com...
Page 3: ...BES M12EH1 L01C40B S04G L04 BES M18EH1 L01C80B S04G L04 IO Link Konfiguration deutsch...
Page 4: ...www balluff com...
Page 95: ...BES M12EH1 L01C40B S04G L04 BES M18EH1 L01C80B S04G L04 IO Link Configuration english...
Page 96: ...www balluff com...
Page 187: ......