54
english
5.5.6 Events
Event Code
Event Type
Description
Device Status
0x8D07 (36103)
Warning
The calculation of the basic statistics was stopped
automatically to avoid a buffer overflow.
0 – Device is
operating properly.
0x8D0E (36110)
Notification
The time has elapsed. This event reports the timeout of
the minimum value/maximum value/average calculation.
It does not report a timeout for the calculation of the
moving average because the timer repeats and it does
not indicate the end of the calculation.
0 – Device is
operating properly.
Tab. 5-28: Basic statistics – Events
5.5.7 Variant Dependence
The functionality is available in all variants.