www.balluff.com
43
english
Speed Lower Limit Low
In combination with
Speed Lower Limit High
, it forms a
threshold value with hysteresis for the
too low
status.
Speed Monitoring Startup Delay
With
Startup Delay
, the time for the startup delay can be
set. The startup delay begins after the supply voltage is
switched on. During the startup delay, speed monitoring
has no function. Speed monitoring starts after the startup
delay has elapsed. The value represents the time in
seconds. The value range is between 0x00 (0) and 0xFF
(255). A value of 0x00 (0) represents no start delay.
Speed Monitoring State
With
Speed Monitoring State
, the current status can be
read.
Value
Meaning
Description
0x00 (0)
Idle
No speed value yet available
0x01 (1)
Too low
Speed value is less than the
lower threshold
0x02 (2)
OK
Speed value is in the suitable
range
0x04 (4)
Too high
Speed value is greater than
the upper threshold
0x08 (8)
Startup
Delay
Startup delay currently
running
0xFF (255) Deactivated
Feature is deactivated
Tab. 5-12: Speed Monitoring State
Speed Monitoring Value
With
Speed Monitoring Value
, the current speed value can
be read.
5.3.5 System Commands
Command
Value
Device Action
0x81 (129)
Application Reset
– Resets writable
parameters to the default value.
0x82 (130)
Reset Factory Settings
– Resets writable
parameters to the default value.
0xAA (170)
Signal Speed Monitoring Reset
– Resets
the speed value and flags.
Tab. 5-13: Speed Monitoring State – System Commands
For an overview of all System Commands, see section 3.5
5
Secondary Device Functions (continued)
BES M12EH1-L01C40B-S04G-L04 / BES M18EH1-L01C80B-S04G-L04
Inductive sensors
Summary of Contents for IO-Link BES M12EH1-L01C40B-S04G-L04
Page 2: ...www balluff com...
Page 3: ...BES M12EH1 L01C40B S04G L04 BES M18EH1 L01C80B S04G L04 IO Link Konfiguration deutsch...
Page 4: ...www balluff com...
Page 95: ...BES M12EH1 L01C40B S04G L04 BES M18EH1 L01C80B S04G L04 IO Link Configuration english...
Page 96: ...www balluff com...
Page 187: ......