System Functions (continued)
6.9
Parameter Manager
6.9.1 Description
The parameter manager is responsible for the saving of
parameters in the permanent memory of the device. On
startup, all stored parameters are read from permanent
memory; if parameters are changed, the data is stored
within the permanent memory by the parameter manager.
All data is protected with a CRC32 checksum. In the event
of damaged memory, the parameter manager outputs the
Parameters not consistent
event.
6.9.2 Events
Event Code
Event Type
Description
Device Status
0x8D24 (36132)
Warning
Parameter write error – for information purposes
only.
0 – Device is operating properly
0x8D25 (36133)
Error
Parameters not consistent – basic settings are
used, service required.
4 – Failure
Tab. 6-29: Parameter manager – Events