www.balluff.com
19
english
Name
Index
Sub-
index
Access
Length
Data Type
Data
Storage
Default
Diagnosis Suppression
Diagnosis Level
Configuration
0x0070
(112)
0
R/W
1 byte
ENUM
Yes
0
Event Code
Suppression
0x0071
(113)
0
R/W
10 byte
UINT16
Yes
0
1-5
R/W
2 bytes
Event Code
Suppression Teach-in
0x0072
(114)
0
W
2 bytes
UINT16
n/a
n/a
Event Code
Suppression Delete
0x0073
(115)
0
W
2 bytes
UINT16
n/a
n/a
Reset Commands
System Commands
0x0002
(2)
0
W
1 byte
UINT8
n/a
n/a
Variant Configuration
Device Variant
0x0055
(85)
0
R/W
2 bytes
ENUM
Yes
2 (ADSS)
Pin Assignment
Pin 4 Function
0x0090
(144)
0
R/W
2 bytes
Yes
Behavior IO-Link
1
R/W
1 byte
ENUM
0x00 Inactive
Mode
2
R/W
1 byte
ENUM
0x01 digital output
Pin 4 Digital
Configuration
0x0091
(145)
0
R/W
4 byte
Yes
Signal Source
1
R/W
2 bytes
ENUM
0x0038 ADSS
Logic
2
R/W
1 byte
ENUM
0x00 normal
Type
3
R/W
1 byte
ENUM
0x02 push pull
Pin 2 Function
0x0093
(147)
0
R/W
2 bytes
Yes
Behavior IO-Link
1
R/W
1 byte
ENUM
0x01 normal operation
Mode
2
R/W
1 byte
ENUM
0x01 digital output
Pin 2 Digital
Configuration
0x0094
(148)
0
R/W
4 byte
Yes
Signal Source
1
R/W
2 bytes
ENUM
0x0038 ADSS
Logic
2
R/W
1 byte
ENUM
0x00 normal
Type
3
R/W
1 byte
ENUM
0x00 PNP
LED Meaning and Configuration
LED Standard
Selection
0x00FD
(253)
0
R/W
1 byte
ENUM
yes
0
3
Overview of IO-Link Data and Functions (continued)
BES M12EH1-L01C40B-S04G-L04 / BES M18EH1-L01C80B-S04G-L04
Inductive sensors
Summary of Contents for IO-Link BES M12EH1-L01C40B-S04G-L04
Page 2: ...www balluff com...
Page 3: ...BES M12EH1 L01C40B S04G L04 BES M18EH1 L01C80B S04G L04 IO Link Konfiguration deutsch...
Page 4: ...www balluff com...
Page 95: ...BES M12EH1 L01C40B S04G L04 BES M18EH1 L01C80B S04G L04 IO Link Configuration english...
Page 96: ...www balluff com...
Page 187: ......