www.balluff.com
51
english
5.5.4 ISDU
Minimum
,
Maximum
,
Average
and
Moving
Average outputs
are output in FLOAT32 format.
Before they are processed further and converted
from FLOAT32 to INT32 or UINT32, the output
signal must be checked to determine whether it
is larger than int32_Max or uint32_Max. If it is
larger, data type UINT64 or INT64 should be
used.
Name
Index
Subindex
Access
Length
Data Type
Data
Storage
Default
Statistics Data
Configuration
0x0426
(1062)
0
R/W
8 byte
Yes
–
Input Signal
1
R/W
2 bytes
ENUM
No
–
Time Period Unit
2
R/W
1 byte
ENUM
No
Seconds
Time Period Value
3
R/W
2 bytes
UINT16
No
1
Moving Average
Window Unit
4
R/W
1 byte
ENUM
No
Measurement
values
Moving Average
Window Value
5
R/W
2 bytes
UINT16
No
100
Statistics Data Output 0x0427
(1063)
0
R
21 bytes
No
–
Minimum
1
R
4 byte
Float32
No
0
Maximum
2
R
4 byte
Float32
No
0
Average
3
R
4 byte
Float32
No
0
Moving Average
4
R
4 byte
Float32
No
0
Number of samples
5
R
4 byte
UINT32
No
0
Status
6
R
1 byte
UINT8
No
0
Tab. 5-21: Basic statistics – ISDU
Statistics Data Configuration: Input Signal
All data types of process data objects can be used for
input configuration, with the exception of Boolean. The
respective Object IDs can be found in the respective
section on the function.
5
Secondary Device Functions (continued)
BES M12EH1-L01C40B-S04G-L04 / BES M18EH1-L01C80B-S04G-L04
Inductive sensors
Summary of Contents for IO-Link BES M12EH1-L01C40B-S04G-L04
Page 2: ...www balluff com...
Page 3: ...BES M12EH1 L01C40B S04G L04 BES M18EH1 L01C80B S04G L04 IO Link Konfiguration deutsch...
Page 4: ...www balluff com...
Page 95: ...BES M12EH1 L01C40B S04G L04 BES M18EH1 L01C80B S04G L04 IO Link Configuration english...
Page 96: ...www balluff com...
Page 187: ......