12
english
3.4
ISDU – Identification Data
Name
Index
Sub-
index
Access
Length
Data Type
Data
Storage
Default
Identification
Vendor Name
0x0010
(16)
0
R
7 byte
STRING
No
“Balluff”
Vendor Text
0x0011
(17)
0
R
15 byte
STRING
No
“www.balluff.com”
Product Name
0x0012
(18)
0
R
[..]
STRING
No
e.g. “BES M12EH1-
L01C40B-S04G-L04
(ADSS)”
Product ID
0x0013
(19)
0
R
[..]
STRING
No
e.g. “BES M12EH1-
L01C40B-S04G-L04
(ADSS)”
Product Text
0x0014
(20)
0
R
[..]
STRING
No
e.g. “Inductive
Proximity Switch - M12
flush”
Serial Number
0x0015
(21)
0
R
16 byte
STRING
No
Hardware Revision
0x0016
(22)
0
R
2 bytes
STRING
No
Firmware Revision
0x0017
(23)
0
R
≤ 10 bytes
STRING
No
Application Specific
Tag
0x0018
(24)
0
R/W
≤ 32 bytes
STRING
Yes
“***”
Function Tag
0x0019
(25)
0
R/W
≤ 32 bytes
STRING
Yes
“***”
Location Tag
0x001A
(26)
0
R/W
≤ 32 bytes
STRING
Yes
“***”
Product Type Code
0x0700
(1792)
0
R
≤ 64 bytes
STRING
No
e.g. “BES M12EH1-
L01C40B-S04G-L04
(ADSS)”
Product Order Code
0x0701
(1793)
0
R
7 byte
STRING
No
e.g. “BES05Y7”
Device Identification
Ping Timeout
0x00FE
(254)
0
R/W
2 bytes
INT
Yes
1
Switching profiles (AdSS)
SSC Parameter SP
0x0038
(56)
0
RW
16 bits
IntT16
Yes
1)
0x0064 (100)
SSC Configuration
Logic
0x0039
(57)
0
RW
8 bits
UIntT8
Yes
0x00
Teach-In Result
0x003B
(59)
0
RO
8 bits
UIntT8
No
–
Transducer Signal
0x01B2
(434)
0
RO
16 bits
IntT16
No
–
1)
Data storage possible for SSC parameters. Switching interval can change after sensor change.
3
Overview of IO-Link Data and Functions (continued)
BES M12EH1-L01C40B-S04G-L04 / BES M18EH1-L01C80B-S04G-L04
Inductive sensors
Summary of Contents for IO-Link BES M12EH1-L01C40B-S04G-L04
Page 2: ...www balluff com...
Page 3: ...BES M12EH1 L01C40B S04G L04 BES M18EH1 L01C80B S04G L04 IO Link Konfiguration deutsch...
Page 4: ...www balluff com...
Page 95: ...BES M12EH1 L01C40B S04G L04 BES M18EH1 L01C80B S04G L04 IO Link Configuration english...
Page 96: ...www balluff com...
Page 187: ......