www.balluff.com
21
english
3.5
System Commands
Command Value
Device Action
0x40 (64)
Teach Apply
– Calculates the switching point for SP1, SP2.
0x41 (65)
Teach SP1
(ADSS:
Teach SP
) – Determines teach point 1 for setpoint 1 and calculates the
switching point.
0x42 (66)
Teach SP2
– Determines teach point 1 for setpoint 2 and calculates the switching point
0x43 (67)
Teach SP1 TP1
(ADSS:
Teach TP1
) – Determines teach point 1 for setpoint 1
0x44 (68)
Teach SP1 TP2
(ADSS:
Teach TP2
) – Determines teach point 2 for setpoint 1
0x45 (69)
Teach SP2 TP1
– Determines teach point 1 for setpoint 2
0x46 (70)
Teach SP2 TP2
– Determines teach point 2 for setpoint 2
0x47 (71)
Teach SP1 Start
(ADSS:
Teach SP Start
) – Starts dynamic teach-in for setpoint 1
0x48 (72)
Teach SP1 Stop
(ADSS:
Teach SP Stop
) – Stops dynamic teach-in for setpoint 1 and calculates
the switching point.
0x49 (73)
Teach SP2 Start
– Starts dynamic teach-in for setpoint 2
0x4A (74)
Teach SP2 Stop
– Stops dynamic teach-in for setpoint 2 and calculates the switching point
0x4E (78)
Teach Reset
– Any active teach-in process is interrupted, all temporarily stored values are reset.
0x4F (79)
Teach Cancel
– Any active teach-in process is interrupted.
0x80 (128)
Device Reset
– Device Reset means a warm start of the device. During this process, the
microcontrollers are restarted and all initializations performed again without any change made to
the parameter values.
0x81 (129)
Application Reset
0x82 (130)
Reset Factory Settings
0xA5 (165)
Maintenance Reset
0xA6 (166)
Switching Counter Reset
– Resets counter value and flags.
0xA7 (167)
Statistics Reset
– Resets all output parameters to 0 and all user settings to the default values.
0xA8 (168)
Statistics Start min/max/avg
– Starts the statistics of the minimum value/maximum value/average
calculation.
0xA9 (169)
Statistics Stop
– Stops statistics operation completely.
0xAA (170)
Signal Speed Monitoring Reset
– Resets the speed value and flags.
0xAC (172)
Statistics Start Moving Average
– Starts the statistics of the moving average calculation.
0xAF (175)
Start Ping
0xC0 (192)
Set Reference Orientation
– Sets the reference orientation of the actual position of the device.
Responses: ACK: command successful, reference stored.
Tab. 3-7: System Commands – Overview
3
Overview of IO-Link Data and Functions (continued)
BES M12EH1-L01C40B-S04G-L04 / BES M18EH1-L01C80B-S04G-L04
Inductive sensors
Summary of Contents for IO-Link BES M12EH1-L01C40B-S04G-L04
Page 2: ...www balluff com...
Page 3: ...BES M12EH1 L01C40B S04G L04 BES M18EH1 L01C80B S04G L04 IO Link Konfiguration deutsch...
Page 4: ...www balluff com...
Page 95: ...BES M12EH1 L01C40B S04G L04 BES M18EH1 L01C80B S04G L04 IO Link Configuration english...
Page 96: ...www balluff com...
Page 187: ......