MN1957
Input / Output 4-29
www.baldormotion.com
NextMove ESB-2
connector
Pin
Name of
signal
Function
Connection on amplifier
(Note: connections may
be labeled differently)
X1
1
0V
Control supply ground
2
+24 V
Control 24 V input
X5
Encoder0
Encoder0 feedback input
Encoder output
X12
9
REL NO
Normally open relay contact
(closed to enable drive)
24 V
10
REL COM
Common relay connection
Enable GND
X13
1
Demand0
Demand output 0
2
AGND
Analog GND
Demand-
3
Shield
Shield connection
(Do not connect)
Table 2: Connector details for minimum system wiring shown in Figure 30