Installation
Azbil Corporation
2-32 MagneW
FLEX+/PLUS+
Electromagnetic Flowmeter Detector
Table 2-7 Recommended inner diameters of gaskets
Bore diameter
mm (inch)
Inner diameter
mm (inch)
1100
(44)
1101±2
(43.35±0.08)
2.5.3: Selecting an installation method
To select an installation method you must determine the following:
• Mounting pipe material (metal or PVC)
• Grounding ring material (SUS or non-SUS)
• Need for a protective plate
• Use of rubber gaskets
CAUTION
The necessary materials and the installation method vary according to the material
of the ring and that of the pipe on which the detector is to be installed. Select the
appropriate method of installation from the following table after confirming the
specifications of the detector to be installed and the conditions of installation.
Improper installation can result in leakage or damage to the pipe flanges.
Table 2-8 Flange detector installation methods
Pipe
material
Grounding ring
material
Installation requirements
See Page
Metal
SUS material
With specified fastening torque
Non-SUS material
With specified fastening torque
PVC
SUS material
With specified fastening torque
With a protective plate
With rubber gaskets and low
fastening torque
Non-SUS material
With specified fastening torque
With a protective plate
With rubber gaskets and low
fastening torque
Summary of Contents for MagneW FLEX+
Page 8: ...Table of Contents...
Page 9: ...Table of Contents...
Page 12: ...List of Figure...
Page 14: ...List of Table...
Page 26: ...Introduction Azbil Corporation 1 12 MagneW FLEX PLUS Electromagnetic Flowmeter Detector...
Page 83: ......
Page 86: ......
Page 88: ......