Azbil Corporation
Installation
MagneW
FLEX+/PLUS+
Electromagnetic Flowmeter Detector
2-29
Table 2-6
Fastening torque for flanged detectors
Nominal
detector bore
diameter
mm (inch)
Flange ratings
Fastening torque
N•m (ft•lb)
kgf•cm
400 mm
(16 inches)
JIS 10K
JIS 20K
JIS G3451 F12
72 - 88
160 - 189
69 - 85
(53.1 - 64.9)
(118.0 - 139.4)
(50.9 - 62.7)
734 - 897
1632 - 1927
704 - 867
JPI 150
JPI 300
ANSI 150
ANSI 300
80 - 98
166 - 195
(59.0 - 72.3)
(122.4 - 143.8)
816 - 999
1693 - 1988
DIN PN10/16
DIN PN25
72 - 88
199 - 234
(53.1 - 64.9)
(146.8 - 172.6)
734 - 897
2029 - 2386
500 mm
(20 inches)
JIS 10K
JIS 20K
JIS G3451 F12
114 - 133
173 - 204
133 - 161
(84.1 - 98.1)
(127.6 - 150.5)
(98.1 - 118.7)
1162 - 1356
1764 - 2080
1356 - 1642
JPI 150
JPI 300
ANSI 150
155 - 189 (114.3 - 139.4)
1581 - 1927
DIN PN10/16
DIN PN25
106 - 129
214 - 251
(78.2 - 95.1)
(157.8 - 185.1)
1081 - 1315
2182 - 2559
600 mm
(24 inches)
JIS 10K
JIS 20K
JIS G3451 F12
184 - 216
267 - 315
127 - 154
(135.7 - 159.3)
(196.9 - 232.3)
(93.7 - 113.6)
1876 - 2203
2723 - 3212
1295 - 1570
JPI 150
JPI 300
ANSI 150
214 - 262 (157.8 - 193.2)
2182 - 2672
DIN PN10/16
DIN PN25
153 - 185
292 - 343
(112.8 - 136.4)
(215.4 - 253.0)
1560 - 1886
2978 - 3498
700 mm
(28 inches)
JIS 10K
JIS G3451 F12
134 - 163 (98.9 - 120.3)
1367 - 1663
800 mm
(32 inches)
JIS 10K
JIS G3451 F12
187- 228 (138.0 - 168.3)
1908 - 2327
900 mm
(40 inches)
JIS 10K
JIS G3451 F12
193 -235 (142.4- 173.4)
1969 - 2398
1000 mm
(36 inches)
JIS 10K
JIS G3451 F12
262 - 320 (193.4- 236.2)
2673 - 3265
1100 mm
(44 inches)
JIS 10K
JIS G3451 F12
300 - 360 (221.4 - 265.7)
3061 - 3673