![Azbil MagneW FLEX+ User Manual Download Page 60](http://html1.mh-extra.com/html/azbil/magnew-flex/magnew-flex_user-manual_3042665060.webp)
Installation
Azbil Corporation
2-34 MagneW
FLEX+/PLUS+
Electromagnetic Flowmeter Detector
2.5.5: Installation on a metal pipe using non-SUS
grounding ring material
The installation method described in this section is for installation on a metal pipe
using non-SUS grounding ring material. For the installation method corresponding to
any other combination of materials, refer to Table 2-8 on page 2-32.
PTFE gaskets are provided for this type of installation. If you supply the gaskets,
Azbil Corporation recommends non-rubber gaskets such as joint sheet or PTFE.
To install a flanged detector on a metal pipe using non-SUS grounding ring
material and a specified torque:
• Install the detector as shown in the following illustration. The torque level for
tightening the bolts is not related to the gasket material.
See Table 2-6 on page 2-26 for the appropriate torque.
See Table 2-7 on page 2-31 for the inner diameter of the gasket.
Lining
Grounding ring
PTFE gasket
(supplied)
Figure 2-25 Installation on a metal pipe using non-SUS grounding ring material
and a specified torque