UMAX180800, 20 Thermocouple, 2 RTD, 4 Inputs, 6 Relays Dual CAN Controller
Version 1
Page: 47-71
Thermocouple Type
Drop List
4, K Type
Refer to Section 3.4
Enable Cold Junction Compensation
Drop List
1
Refer to Section 3.4
High Shutdown Temperature
-200
0…2000
1000
Refer to Section 3.4
Low Shutdown Temperature
-
2000…2000
0
Refer to Section 3.4
High Warning Temperature
-
2000…2000
1000
Refer to Section 3.4
Low Warning Temperature
-
2000…2000
0
Refer to Section 3.4
High Warning Voltage
-
78…78
70
Refer to Section 3.4
Low Warning Voltage
-
78…78
0
Refer to Section 3.4
Code Data Low Limit
0x00...0xFFFFFF
0
Refer to Section 3.4
Code Data High Limit
0x00...0xFFFFFF
0
Refer to Section 3.4
Event Generates a DTC in DM1
Drop List
0, Disabled
Refer to Section 3.14
Event Cleared only by DM11
Drop List
0, False
Refer to Section 3.14
Lamp Set by Event in DTC
Drop List
0, Protect
Refer to Section 3.14
SPN for Event used in DTC
0x00…0x7FFFF
-
Refer to Section 3.14
FMI for Event used in DTC
Drop List
0
Refer to Section 3.14
Delay Before Sending DM1
0…60000
1000
Refer to Section 3.14
4.3.5 Relay Output Setpoints
The Relay Output setpoints are defined in Section 3.6.Refer to that section for detailed
information on how these setpoints are used. The screen capture below in Figure 17 displays
the available setpoints for each of the Thermocouple Inputs. Table 40 below highlights the
allowable ranges for each setpoint.