UMAX180800, 20 Thermocouple, 2 RTD, 4 Inputs, 6 Relays Dual CAN Controller
Version 1
Page: 45-71
4.3.3 Universal Input Setpoints
The Universal Input setpoints are defined in Section 3.3.Refer to that section for detailed information on how
these setpoints are used. The screen capture below in Figure 15 displays the available setpoints for each of the
Universal Inputs.
Table 38 below highlights the allowable ranges for each setpoint. Due to the same default
settings for each diagnostic, it will be mentioned in the table only once.
Figure 15: Screen Capture of Default Universal Input Setpoints
Table 38. Default Universal Input Setpoints
Name
Range
Default
Notes
Input Type
Drop List
1, Voltage Input
Refer to Section 3.3
Input Voltage Range
Drop List
0, 0-5V
Refer to Section 3.3
Input Current Range
Drop List
0, 0-20mA
Refer to Section 3.3
Input Range Min
Depends on Input Type
0
Refer to Section 3.3
Input Range Min
Depends on Input Type
5
Refer to Section 3.3
Voltage LoZ Input
Drop List
0, Pull Down Disabled
Refer to Section 3.3
Analog Input Filter
Drop List
Off
Refer to Section 3.3
Pull-Up/Pull-Down Resistor
Drop List
0, No Pull
Refer to Section 3.3
Input Polarity
Drop List
0, Active High
Refer to Section 3.3
Discrete Input Debounce Time
0…65000
50
Refer to Section 3.3
Frequency Range
0
0, 1Hz…10kHz
Refer to Section 3.3
Frequency/PWM Debounce Filter
Drop List
0, No Filter
Refer to Section 3.3
Frequency/PWM Debounce
Averaging
Drop List
Input Not Implemented
Refer to Section 3.3
Event Generates a DTC in DM1
Drop List
0, Disabled
Refer to Section 3.14
Event Cleared only by DM11
Drop List
0, False
Refer to Section 3.14