UMAX180800, 20 Thermocouple, 2 RTD, 4 Inputs, 6 Relays Dual CAN Controller
Version 1
Page: 67-71
Signal Inputs (4)
4 Universal Signal Inputs configurable as:
Voltage, Current, Frequency, PWM or Digital
12-bit Analog to Digital resolution (Voltage and Current)
Protected against shorts to GND or +Vps
Voltage Types:
0-5Vdc (Input impedance 204 k
Ω)
or 0-10Vdc (Input impedance 134 k
Ω)
1mV resolution, ac/- 0.2% error
Current Types:
0-20 mA (Input impedance 249 k
Ω)
or 4-20 mA (Input impedance 249 k
Ω)
1uA resolution, ac/- 0.2% error
Frequency Type:
Range: 0.5 Hz to 10 kHz
0.01% resolution, ac/- 0.1% error
PWM Type:
PWM Signal Frequency: 1 Hz to 10 kHz
PWM Duty Cycle: 0 to 100%
0.01% resolution, ac/- 1% error
Digital Type:
Active High with 10K Pullup
or Active Low with 10K Pulldown resistor to GND
Amplitude: up to +Vsupply
6.3 Outputs
Relay Outputs (6)
6 Form C relay outputs
5 A at 30 VDC
NO, COM and NC pins are available.
6.4 Communication
CAN
2 CAN 2.0B port, protocol SAE J1939
Auto-Baud-Rate-Detection
400VDC isolation
The two CAN channels are fully isolated from one another in the hardware which
allows for different CAN networks to be connected. In the software, each will also
act independently where incoming or outgoing messages can be configured to
receive or send on a specific CAN channel.
Network Termination
According to the CAN standard, it is necessary to terminate the network with
external termination resistors. The resistors are 120 Ohm, 0.25W minimum,
metal film or similar type. They should be placed between CAN_H and CAN_L
terminals at both ends of the network.
Ethernet
1 port 10/100 Mbit Ethernet compliant
10BASE-T. 100BASE-Tx (Auto-configuration and full-duplex is supported.)
Auto-MDIX
Modbus TCP/IP
6.5 General Specifications
Microprocessor
STM32F407ZGT6, 1 Mbyte Flash Memory, 192+4 Kbyte SRAM
Control Logic
User programmable functionality with the Electronic Assistant
Refer to the User Manual.
User Interface
Electronic Assistant, P/N: AX070502
Updates for the EA are found on
Vibration
Pending
Shock
Pending
Operating Temperature Range
-40 to 85 ºC (-40 to 185 ºF)
Storage Temperature Range
-50 to 120 ºC (-58 to 248 ºF)
Humidity
Protected against 95% humidity non-condensing, 30 ºC to 60 ºC
Protection
IP67
Weight
3.1 lb. (0.141 kg)