UMAX180800, 20 Thermocouple, 2 RTD, 4 Inputs, 6 Relays Dual CAN Controller
Version 1
Page: 44-71
Figure 14: Screen Capture of Default RTD Input Setpoints
Table 37. Default RTD Setpoints
Name
Range
Default
Notes
RTD Type
Drop List
2, Three Wires
Refer to Section 3.5
Callendar Van Dusen Constant A
-
100…100
3.90830
Refer to Section 3.5
Callendar Van Dusen Constant B
-
100…100
-5.77500
Refer to Section 3.5
Callendar Van Dusen Constant C
-
100…100
-4.18301
Refer to Section 3.5
High Shutdown Temperature
-
2000…2000
1000
Refer to Section 3.5
Low Shutdown Temperature
-
2000…2000
0
Refer to Section 3.5
High Warning Temperature
-
2000…2000
1000
Refer to Section 3.5
Low Warning Temperature
-
2000…2000
0
Refer to Section 3.5
High Warning Resistance
-
20…200
200
Refer to Section 3.5
Low Warning Resistance
-
20…200
0
Refer to Section 3.5
High Warning Code
0x00…0xFFFFFF
0
Refer to Section 3.5
Low Warning Code
0x00…0xFFFFFF
0
Refer to Section 3.5
Event Generates a DTC in DM1
Drop List
0, Disabled
Refer to Section 3.14
Event Cleared only by DM11
Drop List
0, False
Refer to Section 3.14
Lamp Set by Event in DTC
Drop List
0, Protect
Refer to Section 3.14
SPN for Event used in DTC
0x00…0x7FFFF
-
Refer to Section 3.14
FMI for Event used in DTC
Drop List
0
Refer to Section 3.14
Delay Before Sending DM1
0…60000
1000
Refer to Section 3.14