![Avaya Octel 200 Installation And Maintenance Manual Download Page 281](http://html.mh-extra.com/html/avaya/octel-200/octel-200_installation-and-maintenance-manual_3026450281.webp)
Maintenance
Commands
6-39
Octel 200/300
S.4.1
PB60019
−
01
Table 6-2 Abbreviations for Channel/Port State (continued)
Port State
Abbreviation
Description
OMR
OCTELNET MESSAGE RECEIVE
OMS
OCTELNET MESSAGE SEND
QAD
COLLECTING AN ADDRESS FOR A QUICK MESSAGE
QCK
RECORDING A QUICK MESSAGE OR MESSAGE AFTER CALL
PAC
PERSONAL ASSISTANCE CONFIGURATION
PDL
PERSONAL DISTRIBUTION LISTS
QS
1
QSIG TRANSFER IN PROGRESS
−
STATE 1
QS2
QSIG TRANSFER COMPLETION
−
STATE 2
RDY
WAITING FOR COMMAND AT READY
RNM
USER RECORD OWN NAME
SCR
SCRIPTED GREETING
SLQ
SELECT MESSAGE QUEUE
STA
START COMMAND PROCESSING
STR
START OF INITIAL LOGON BEFORE READY
TST
SELFTEST IN PROGRESS OR PORT HAS FAILED SELFTEST
VMR
NET MESSAGE RECEIVED - PROTOCOL 2
VMS
NET MESSAGE SEND - PROTOCOL 2
WFA
WAITING FOR MAILBOX ADDRESS AFTER RECEIVING #
WFD
WAITING FOR FIRST DIGIT AFTER ANSWERING CALL
XPR
TRANSPARENCY STATE FOR DPNSS/qsig (path replacement is in progress)
5KI
VMX 5000 USER INTERFACE
Alarm Test
The
TEST ALARM
command tests the alarm callout feature. At the @ prompt, enter:
TE A
Enter
The message server attempts to call the string configured in System Parameter 31 — ALARM
NUMBER. If successful, the person answering the alarm call hears a message similar to the following:
“Beep-Beep-Beep-Beep. This is an alarm call from message server number 123. Error type O has
occurred. Press star to acknowledge alarm notification or press pound to connect to the modem.”
If not acknowledged, the message server disconnects the call after 1 minute and retries it every 10
minutes, until it is acknowledged (the listener presses
*
).
To log on for remote access, proceed as follows:
1. Press
#
. The line
Beeps
for up to 3 minutes, which allows time to connect the modem and the
terminal.
2. Press
#
when ready. This connects the modem, which enables remote access to the Octel 200/300.
.
If the person answering the alarm call does not enter a second
#
, the server disconnects the call
and continues to retry every 10 minutes, until the call is acknowledged.
Summary of Contents for Octel 200
Page 8: ......
Page 14: ......
Page 26: ......
Page 28: ......
Page 106: ......
Page 108: ......
Page 122: ......
Page 126: ......
Page 184: ......
Page 228: ......
Page 242: ......
Page 306: ......
Page 308: ......
Page 310: ......
Page 368: ......
Page 384: ......
Page 386: ......
Page 448: ......
Page 514: ......
Page 534: ......
Page 536: ......
Page 538: ......
Page 552: ......
Page 558: ......
Page 584: ......
Page 586: ......
Page 588: ......