Hard drive bay
SCSI
channel
SCSI ID
Logical drive label
a
a. RAID pairs (logical drives) consist of the following pairs: hard drives 1 and 4,2 and 5,
and 3 and 6. these pairs are represented in the software with the lables A01-01 and A01-02,
A02-01 and A02-02, and A03-02, A03-02 where the first number is the logical drive number
(for example, A03) and the second number indicates if it is the primary or secondary hard
drive (01 for primary and 02 for secondary)
To replace hot-pluggable SCA SCSI hard drives
1.
Caution:
Risk of equipment damage
Use an ESD wrist strap to protect static-sensitive components.
Ensure the new hard drive has the SCSI ID set to 0, termination disabled, and parity
checking enabled.
2. Open the front bezel doors.
3. Locate the SCA SCSI drive frame below a cooling fan and beside the media drive.
4. Loosen the two thumbscrews on the carrier of the faulty hard drive, and remove the
carrier from the chassis.
RAID SCSI hard drive configuration
Avaya CallPilot® 1002rp Server Maintenance and Diagnostics
December 2010 99
Summary of Contents for callpilot 1002rp
Page 1: ...Avaya CallPilot 1002rp Server Maintenance and Diagnostics 5 0 NN44200 701 01 05 December 2010 ...
Page 4: ...4 Avaya CallPilot 1002rp Server Maintenance and Diagnostics December 2010 ...
Page 10: ...10 Avaya CallPilot 1002rp Server Maintenance and Diagnostics December 2010 ...
Page 18: ...About this guide 18 Avaya CallPilot 1002rp Server Maintenance and Diagnostics December 2010 ...
Page 118: ...RAID operations 118 Avaya CallPilot 1002rp Server Maintenance and Diagnostics December 2010 ...