Figure 18: Fuse receptacle
5. Slide the fuse receptacle out of the fuse chamber.
Note:
Observe how the blown fuse is positioned in the receptacle.
6. Remove the blown fuse from the fuse receptacle.
7. Install the approved replacement fuse. Use a flat-blade screwdriver to screw in the
fuse receptacle with a push and 1/4 clockwise turn.
8. Slide the fuse receptacle back into its chamber.
9. Fasten the fuse receptacle with a flat-blade screwdriver.
10. Plug the power cable back into the power input socket on the server.
11. Plug the power cable into the wall outlet.
12. Power on the server.
Important:
If the fuse blows after replacement, swap one power supply module with the other. If this
does not work, call your Avaya customer support representative.
Replacing the alarm board
The 1002rp server alarm board and status panel are used to monitor and indicate the server
status. The basic hardware check on page
on page 20 fails if the board is
defective or damaged. When these units are damaged, replace them immediately.
Replacing basic chassis components
90 Avaya CallPilot® 1002rp Server Maintenance and Diagnostics
December 2010
Summary of Contents for callpilot 1002rp
Page 1: ...Avaya CallPilot 1002rp Server Maintenance and Diagnostics 5 0 NN44200 701 01 05 December 2010 ...
Page 4: ...4 Avaya CallPilot 1002rp Server Maintenance and Diagnostics December 2010 ...
Page 10: ...10 Avaya CallPilot 1002rp Server Maintenance and Diagnostics December 2010 ...
Page 18: ...About this guide 18 Avaya CallPilot 1002rp Server Maintenance and Diagnostics December 2010 ...
Page 118: ...RAID operations 118 Avaya CallPilot 1002rp Server Maintenance and Diagnostics December 2010 ...