![Avaya callpilot 1002rp Maintenance And Diagnostics Download Page 140](http://html1.mh-extra.com/html/avaya/callpilot-1002rp/callpilot-1002rp_maintenance-and-diagnostics_3028038140.webp)
Figure 38: SBC card connectors and jumpers.
To replace the SBC cardDANGER
1.
Danger:
Risk of explosion
The SBC has a lithium battery installed. If you are discarding the SBC, dispose
of used batteries according to the manufacturer's instructions. Replacement of
the battery with an incorrect type also raises the risk of an explosion.
Power down the server.
2. Disconnect the power cord.
3. Remove the top cover.
4. Disconnect and label all cables from the SBC card. See SBC card connectors and
on page 138 to locate the SBC card.
5. Disconnect and label cables from the SBC card faceplate.
6. Loosen and remove the screw that is securing the SBC card.
7. Loosen and remove the screw located at the top of the card faceplate.
8. Loosen the SBC and pull it up from the backplane.
Maintaining the Pentium III SBC card
140 Avaya CallPilot® 1002rp Server Maintenance and Diagnostics
December 2010
Summary of Contents for callpilot 1002rp
Page 1: ...Avaya CallPilot 1002rp Server Maintenance and Diagnostics 5 0 NN44200 701 01 05 December 2010 ...
Page 4: ...4 Avaya CallPilot 1002rp Server Maintenance and Diagnostics December 2010 ...
Page 10: ...10 Avaya CallPilot 1002rp Server Maintenance and Diagnostics December 2010 ...
Page 18: ...About this guide 18 Avaya CallPilot 1002rp Server Maintenance and Diagnostics December 2010 ...
Page 118: ...RAID operations 118 Avaya CallPilot 1002rp Server Maintenance and Diagnostics December 2010 ...