![Avaya callpilot 1002rp Maintenance And Diagnostics Download Page 82](http://html1.mh-extra.com/html/avaya/callpilot-1002rp/callpilot-1002rp_maintenance-and-diagnostics_3028038082.webp)
The cable kit part number for all locations, except EMEA, is FR029367. At EMEA locations,
use part number N0029367.
• Only qualified field technicians who are familiar with Avaya CallPilot and RAID should
attempt this procedure.
• A full-system backup and RAID drive consistency check must be performed prior to
replacing the SCSI power cable. These can both be performed while the server is online.
• If at any step in the procedure, the result is not as indicated, stop and contact your next
level of support for assistance before continuing.
To replace the SCSI power cable
1. Log into the CallPilot server.
2. Launch the MegaRAID client to check the status of the RAID sub-system:
a. Click Start → Programs → MegaRAID Client.
b. Open the Server Selection window.
c. Select Access Mode → Full Access and click OK.
Result: The MegaRAID Power Console Plus window appears.
Figure 11: MegaRAID Power Console Plus
3. Open the Physical Devices window and check the drive pair settings. The table
below shows the correct settings.
Replacing basic chassis components
82 Avaya CallPilot® 1002rp Server Maintenance and Diagnostics
December 2010
Summary of Contents for callpilot 1002rp
Page 1: ...Avaya CallPilot 1002rp Server Maintenance and Diagnostics 5 0 NN44200 701 01 05 December 2010 ...
Page 4: ...4 Avaya CallPilot 1002rp Server Maintenance and Diagnostics December 2010 ...
Page 10: ...10 Avaya CallPilot 1002rp Server Maintenance and Diagnostics December 2010 ...
Page 18: ...About this guide 18 Avaya CallPilot 1002rp Server Maintenance and Diagnostics December 2010 ...
Page 118: ...RAID operations 118 Avaya CallPilot 1002rp Server Maintenance and Diagnostics December 2010 ...