High
-S
peed
Input
and
Pulse
O
utput
Features
3--49
High-Speed Input and Pulse Output Features
DL105 PLC User Manual, 3rd Edition
Recall that V7633 is the HSIO Mode Select register. Refer to the diagram below. Use
BCD 50 in the lower byte to select High-Speed Counter Mode. Use BCD 00 or 20 in
the upper byte as required. Combine the two bytes into a data word “xx50”, for writing
to V7633.
0
15 14 13 12
Memory Location V7633
11
10
1
2
3
4
5
6
7
8
9
Bits
0
0
1
0
0
0
1
0
1
0
0
HSIO Mode Setup (BCD)
Miscellaneous Setup (BCD)
0
0
0
0
00 = Power Up in Previous Mode
20 = Power Up in Run Mode Always
50 = Pulse Catch Input
2
0
0
5
0
Choose the most convenient method of programming V7633 from the following:
S
Include load and out instructions in your ladder program
S
Direct
SOFT’s memory editor
S
Use the Handheld Programmer D2--HPP
We recommend using the first method above so that the HSIO setup becomes an
integral part of your application program. An example program later in this section
shows how to to this.
The configurable discrete input options for Pulse Catch Mode are listed in the table
below. Input X0 is the pulse input, and must have “0005” loaded into it configuration
register V7634. Inputs X1, X2, and X3 can only be filtered inputs. Each input has its
own configuration register and filter time constant.
Input
Configuration
Register
Function
Hex Code
Required
X0
V7634
Pulse Catch Input
0005
X1
V7635
Filtered Input
xx06 (xx = filter time)
X2
V7636
Filtered Input
xx06 (xx = filter time)
X3
V7637
Filtered Input
xx06 (xx = filter time)
Setup for Mode 50
X Input
Configuration
Summary of Contents for DL105
Page 2: ...DL105 PLC User Manual Manual Number D1 USER M...
Page 308: ...1B DL105 Error Codes In This Appendix Error Code Table...
Page 314: ...1C Instruction Execution Times In This Appendix Introduction Instruction Execution Times...
Page 324: ...1D Special Relays In This Appendix DL105 PLC Special Relays...
Page 327: ...1E PLC Memory In This Appendix DL105 PLC Memory...